Ceiling fan won’t run, wobbles or remote fails
Dead fan, hum or missing speeds, a wobble, or a remote that quit. Supply, receiver, capacitor, switch or mounting.
Before you start
How much electrical experience do you have?
This sets how much detail each step shows. You can change it any time.
Showing detail
How it works
Most AC ceiling fans use a capacitor motor. The pull-chain or wall speed control switches different capacitor sections into the circuit to set the speed, so a weak capacitor causes slow speeds, a hum or missing speeds. A remote receiver in the canopy switches the motor and light from a radio signal. DC-motor fans have an electronic control that is the drive, so they can’t be run without it. The box has to be listed for fan support, because a fan is a moving, vibrating load hung from it.
Every question and answer in this guide. Tap “Step by step” to walk through it.
- What’s wrong with the fan?
- Won’t run at allTest: Measure the supply at the canopyExpect: About 120 V on both.
- About 120 VWhat’s in the canopy?
- A receiver, AC motor fanTest: Bypass the receiver to test the motor
- Yes, it runsA failed remote receiver
- No, still deadTest: Test the speed switchExpect: Each position connects common to the outputs shown on the switch diagram, and off connects nothing.
- A position doesn’t connect, or the chain spins freelyA failed pull-chain speed switch
- Switch tests goodA failed fan motor
- No receiver, pull-chain fanTest: Test the speed switchExpect: Each position connects common to the outputs shown on the switch diagram, and off connects nothing.
- A position doesn’t connect, or the chain spins freelyA failed pull-chain speed switch
- Switch tests goodA failed fan motor
- DC motor fanA DC fan with power at the canopy
- A receiver, AC motor fanTest: Bypass the receiver to test the motor
- About 0 VNo power reaching the fan
- About 120 VWhat’s in the canopy?
- Hums, runs slow or is missing speedsTest: Measure the fan capacitorExpect: Each section close to its marked value, within the tolerance printed on the case.
- A section reads low or openA weak or failed fan capacitor
- Every section is close to its marked valueTest: Test the speed switchExpect: Each position connects common to the outputs shown on the switch diagram, and off connects nothing.
- A position doesn’t connect, or the chain spins freelyA failed pull-chain speed switch
- Switch tests goodA failed fan motor
- Hums, and it’s on a light dimmerA light dimmer controlling the fan motor
- WobblesTest: Check the box and mounting
- Box isn’t rated for a fan, or the box movesBox not rated or not secure for a fan
- Loose screws, downrod or bent blade ironLoose or bent mounting hardware
- Everything is tight and trueBlade imbalance
- Remote or wall control doesn’t workDid the remote ever work with this fan?
- New install, new remote or just changed batteriesRemote and receiver not paired
- Worked before, then quitTest: Measure the supply at the canopyExpect: About 120 V on both.
- About 120 VWhat’s in the canopy?
- A receiver, AC motor fanTest: Bypass the receiver to test the motor
- Yes, it runsA failed remote receiver
- No, still deadTest: Test the speed switchExpect: Each position connects common to the outputs shown on the switch diagram, and off connects nothing.
- A position doesn’t connect, or the chain spins freelyA failed pull-chain speed switch
- Switch tests goodA failed fan motor
- No receiver, pull-chain fanTest: Test the speed switchExpect: Each position connects common to the outputs shown on the switch diagram, and off connects nothing.
- A position doesn’t connect, or the chain spins freelyA failed pull-chain speed switch
- Switch tests goodA failed fan motor
- DC motor fanA DC fan with power at the canopy
- A receiver, AC motor fanTest: Bypass the receiver to test the motor
- About 0 VNo power reaching the fan
- About 120 VWhat’s in the canopy?
- Won’t run at allTest: Measure the supply at the canopyExpect: About 120 V on both.